F-MXCH-PIMF-FR

These cables are used for fixed installation on board of ships at all areas & open decks and safety circuits where in event of fire, circuit integrity is required in order to maintain a p...

  • These cables are used for fixed installation on board of ships at all areas & open decks and safety circuits where in event of fire, circuit integrity is required in order to maintain a process or to safety shutdown the process.

Note

  • They have electromagnetic properties.

Design Standards

  • IEC 60092-350
  • IEC 60092-351
  • IEC 60092-359
  • IEC 60092-376

Conductor IEC 60228 CLASS-2 OR CLASS 5 TINNED OR PLAIN C0PPER
Insulation MICA TAPE+ IEC 60092-351 CROSS-LINKED HFFR COMPOUND
Colour code BLUE- WHITE WITH NUMBERED
Invidual screen PES TAPE TINNED COPPER DRAIN WIRE AL - PES TAPE
Stranding PAIRWISE / SCREENED PAIRS IN LAYERS
Wrapping PES - TAPE
Outer Screen TINNED COPPER OR PLAIN COPPER BRAIDING (MIN.%90 COVERAGE)
Outer sheath IEC 60092-359 HFFR COMPOUND
Sheath colour ORANGE OR GREEN

INSULATION
RESISTANCE (MIN)
TEST
VOLTAGE
OPERATING
VOLTAGE
BENDING
RADIUS
TEMP. RANGE FLAME RETARDANT TEST
MΩxKm
500
1,5 Kv A.C. 150/250 V (300V) 8 x D -40ºC+90ºC IEC 60332-1-2
IEC 60332-3-22 CAT A
SMOKE
DENSITY
TEST ON CORROSIVENESS OF
COMBUSTION GASES
HALOGEN-FREE
TEST
CIRCUIT INTEGRITY(FE 180) CIRCUIT INTEGRITY
WITH SHOCK
IEC 61034-2 IEC 60754-2 IEC 60754-1 IEC 60331-21 IEC 60331-1
IEC 60331-2

CODE NR. CROSS SECTION
(mm2)
OVERALL DIAMETER
(mm)
COPPER WEIGHT
(kg/km)
APPROX. WEIGHT
(kg/km)
STANDARD LENGTH
(mt)
352150027
2 x 2 x 0,50